Place of Origin: | China |
Brand Name: | TRT or OEM |
Certification: | CE,CB |
Model Number: | TRT-30LTASHP-HC |
Minimum Order Quantity: | 1 |
---|---|
Price: | Negotiable |
Packaging Details: | plywood |
Delivery Time: | 15-20 days |
Payment Terms: | TT |
Supply Ability: | 1000 PCS a month |
TRT-30LTASHP-HC22 | TRT-30LTASHP-HC38 | TRT-50LTASHP-HC22 | |||
Metel plate | Galvanized steel/Spray/Gray/White (304 Stainless Steel is optional) | ||||
Body size(L*W*H) | 830*420*1160 | 830*420*1160 | 1230*430*1300 | ||
Compressor | Copeland ZW30KSE*1 | Copeland ZW34KSE*1 | Copeland ZW52KSE*1 | ||
Refrigerant | R407C/1.8kg*1 | R407C/1.8kg*1 | R407C/2.1kg*1 | ||
Power Supply | 220V/50Hz | 380V/50Hz | 220V/50Hz | ||
Condenser | Tube in Tube | Tube in Tube | Tube in Tube | ||
φ42*3M | φ42*3M | φ42*5M | |||
Evaporator | 300-785-250*600 | 300-785-250*600 | 320-700*1200 | ||
U-2/φ9.52/25UPipe | U-2/φ9.52/25UPipe | L-2/φ9.52/25UPipe | |||
Plate heat exchanger(Economizer) | B3-16-16 | B3-16-16 | B3-16-18 | ||
Liquid Storage Tank | 145VW-B04-A*1 | 145VW-B04-A*1 | 145VW-B04-A*1 | ||
Gas-liquid separator | LF8W5A-03A*1 | LF8W5A-03A*1 | KFR120WLG-A*1 | ||
Four-way Valve | SHF-11-45D1*1 | SHF-11-45D1*1 | SHF-20A-46*1 | ||
Thermostatic expansion valve | 1RT+3RT | 1RT+3RT | 2RT+5RT | ||
AC Contactor | (220V-25A)*1 | (220V-18A)*1 | (220V-32A)*1 | ||
Motor/ Fan Blade | 90W*1/φ490*1 | 90W*1/φ490*1 | 90W*2/φ490*2 | ||
Control | Single System | Single System | Single System | ||
Low Pressure Switch | 0.1/0.15MPa | 0.1/0.15MPa | 0.1/0.15MPa | ||
High Pressure Switch | 2.4/3.0MPa | 2.4/3.0MPa | 2.4/3.0MPa | ||
Power Line | 3*2.5mm2 | 3*2.5mm2+2*1.5mm2 | 3*6mm2+2*2.5mm2 | ||
Packing | Polywood packing | Polywood packing | Polywood packing | ||
Cooling | 35℃ | Cooling Capacity(kW) | 6.65 | 7.23 | 12.3 |
Input power(kW) | 2.32 | 2.59 | 4.25 | ||
Rated Current(A) | 11 | 6 | 18 | ||
EER | 2.87 | 2.79 | 2.89 | ||
Rated inlet/outlet water Temp(℃) | 12/7 | 12/7 | 12/7 | ||
Water Flow(m3/H) | 1.43 | 1.55 | 2.64 | ||
Heating | 7℃ | Heating Capacity(kW) | 8.43 | 9.4 | 16.8 |
Input Power(kW) | 2.32 | 2.59 | 4.25 | ||
Rated Current(A) | 11 | 6 | 18 | ||
COP | 3.63 | 3.63 | 3.95 | ||
Rated inlet/outlet water Temp(℃) | 40/45 | 40/45 | 40/45 | ||
Water Flow(m3/H) | 1.81 | 2.02 | 3.61 | ||
-10℃ | Heating Capacity(kW) | 5.38 | 6.05 | 10.6 | |
Input Power(kW) | 2.25 | 2.55 | 4.2 | ||
COP | 2.39 | 2.37 | 2.52 | ||
-20℃ | Heating Capacity(kW) | 4.75 | 5.27 | 9.2 | |
Input Power(kW) | 2.2 | 2.48 | 4.1 | ||
COP | 2.16 | 2.13 | 2.24 | ||
Waterproof Grade | IPX4 | IPX4 | IPX4 | ||
Anti-electric shock Rate | I | I | I | ||
Noise(dB(A)) | ≤55 | ≤55 | ≤58 | ||
Net Weight/ Gross Weight(kg) | 106/114 | 106/114 | 150/160 | ||
Pipe size/ Inner diameter(mm) | DN25 | DN25 | DN25 |
Description
Electric parts and water system is completely cut off, ensuring security water use, no pollution to the atmosphere and free of greenhouse effect and it is the safest water heater
Our heat pumps with special designing possess better climatic adaptability, can work from -25℃ to 43℃.
Heat pump water heater is a high efficient transferring heating equipment which is driven by electricity. The operating cost is only 1/4 of electric water heater, 1/3 of gas water heater.
Adopting intelligent computerized automatic control system, no manual cost, easy to operate, convenient, make heat pump work safely and reliably.
Control panel with modularized unit design can control more flexible heat pumps packs, with user-friendly operating system interface, easy to operate..
Adopting world-class Enthalpy potential laboratory to test heat pumps, except basic testing items, we also test heat pump in the ambient of temperature of -30℃ to test our heat pump performance.
Heat pump is applied to hot water for household and commercial use like families, schools, hospitals, shower center, swimming pools, etc. and industrial use like electroplating, drying, etc.
Competitive Advantage:
Adopting the most advanced low temp Enhanced Vapors Injection compressor technology which can help heat pump work steadily even at temperature of -25℃.
EVI heat pump can work from -25℃.to 43℃. Widely used in different environment.
3. Higher heating capacity:
Using enlarging evaporator extracting more heat energy from air will increase COP.
When the ambient is below zero degree, the unit is in standby mode more than 30 minutes, Automatic anti-freezing device will be started up so that the unit will be protecting in lower temperature.